10 Meter pole

10 Mtr/270 KG PSC Pole

The Guaranteed Particulars of PSC Poles 10 Mtr. 270 Kg.

1. Working load : 270 Kg.

2. Factor of safety : 2.5

3. Ultimate Load : 675 Kgs.

4. Dimensions :
(a) Bottom Cross-Section: 406 x 165 mm.
(b) Top Cross-Section: 127 x 165 mm.
(c) Total height: 10,050 mm.
(d) Web thickness: 63 mm
(e) Planting Depth: 1675 mm.

5. No. of Windows : 09 nos.

6. No. of 20mm dia. holes On Front face: 06 nos. (100 mm apart).

7. Minimum requirement:
(a) Cube Test (Each Specimen) : 450 Kg/Cm2 (28 days).: 225Kg/Cm2 (3 days)- at release of Prestress.
(b) Initial tension in HT Steel Wire/Pole. : 70% of 175.00 Kg/mm2

As specified in related I.S.Code

7
8

Our Main Raw Materials

Cement

The cement used in the manufacture of pre-stressed concrete poles is  53 Grade Ordinary Portland cement conforming to IS: 12269 to get 28 days strength of 450 Kg/cm^2.

Aggregate

Coarse aggregates are hard, strong, dense, durable, clear and free from veins and adherent coating, and free from injurious amount of disintegrated pieces, alkali, vegetable material, and other deleterious substances

H.T. Wire

H.T. wire of diameter 4 mm. having a minimum ultimate tensile strength of 17500 kg/cm2 is being used as per approved drawing of the PSC poles

Water

Water is free from chlorides, Sulphate, other salts and organic matter. Potable water will be generally suitable.